Documentation Index
Fetch the complete documentation index at: https://initialabs-mintlify-changelog-interwovenkit-1777853576.mintlify.app/llms.txt
Use this file to discover all available pages before exploring further.
Network Details
Mainnet (interwoven-1)
Testnet (initiation-2)
Network Parameters
Mainnet (interwoven-1)
Testnet (initiation-2)
| Item | Value |
|---|
| Minimum Gas Prices | 0.015uinit |
| Block Gas Limit | 200,000,000 |
| Staking Unbonding Period | 21 days |
| Governance Voting Period | 7 days |
| Item | Value |
|---|
| Minimum Gas Prices | 0.015uinit |
| Block Gas Limit | 200,000,000 |
| Staking Unbonding Period | 7 days |
| Governance Voting Period | 2 days |
Endpoints
You can find a number of RPCs, APIs, and gRPCs for the network in the
Initia Registry repository.
Explorers
Mainnet (interwoven-1)
Testnet (initiation-2)
VIP Parameters
Mainnet (interwoven-1)
Testnet (initiation-2)
| Category | Parameter | Mainnet | Explanation |
|---|
| VIP | stage_interval | 2 weeks | Length of one stage (frequency of esINIT distribution) |
| VIP | vesting_period | 26 stages | Total vesting period for esINIT |
| VIP | minimum_lock_staking_period | 26 weeks | Minimum lock period for an esINIT lock-staking position (“zapping”) |
| VIP | challenge_period | 3 days | Window during which a score-snapshot challenge may be submitted |
| VIP | min_score_ratio | 0.5 | Multiplier applied to the previous stage’s score to determine the minimum score required to fully vest esINIT in the next stage |
| VIP | pool_split_ratio | 0.2 | Portion of total rewards directed to the balance pool |
| VIP | minimum_eligible_tvl | 0 | Minimum INIT TVL required for whitelisting and eligibility for stage rewards |
| VIP | maximum_weight_ratio | 0.4 | Maximum share of gauge votes from a single L2, relative to total votes, counted for esINIT distribution |
| VIP (Operator) | max_commission_rate | 0.25 | Maximum esINIT commission rate a rollup can set |
| VIP (TVL manager) | snapshot_interval | 1 hour | Frequency of TVL snapshots for all L2s |
| VIP (Lock Staking) | min_lock_period | 30 days | Minimum lock period for any lock-staking position |
| VIP (Lock Staking) | max_lock_period | 2 years | Maximum lock period for all lock-staking positions (including esINIT positions) |
| VIP (Lock Staking) | max_delegation_slot | 60 | Maximum number of unique lock-staking positions per user |
| VIP (gauge vote) | cycle_start_time | Same as stage start time | Start time of the first gauge-vote cycle |
| VIP (gauge vote) | cycle_interval | 2 weeks | Length of a gauge-vote cycle |
| VIP (gauge vote) | voting_period | 13 days | Duration of the voting window within a cycle |
| VIP (gauge vote) | max_lock_period_multiplier | 4 | Voting-power multiplier for the maximum lock duration |
| VIP (gauge vote) | min_lock_period_multiplier | 1 | Voting-power multiplier for the minimum lock duration |
| VIP (gauge vote) | pair_multipliers | 1 for all pools | Voting-power multiplier applied to each enshrined liquidity pair |
| Category | Parameter | Testnet | Explanation |
|---|
| VIP | stage_interval | 1 day | Length of one stage (frequency of esINIT distribution) |
| VIP | vesting_period | 26 stages | Total vesting period for esINIT |
| VIP | minimum_lock_staking_period | 1 day | Minimum lock period for an esINIT lock-staking position (“zapping”) |
| VIP | challenge_period | none | Window during which a score-snapshot challenge may be submitted |
| VIP | min_score_ratio | 0.5 | Multiplier applied to the previous stage’s score to determine the minimum score required to fully vest esINIT in the next stage |
| VIP | pool_split_ratio | 0.5 | Portion of total rewards directed to the balance pool |
| VIP | minimum_eligible_tvl | 0 | Minimum INIT TVL required for whitelisting and eligibility for stage rewards |
| VIP | maximum_weight_ratio | 1 | Maximum share of gauge votes from a single L2, relative to total votes, counted for esINIT distribution |
| VIP (Operator) | max_commission_rate | none | Maximum esINIT commission rate a rollup can set |
| VIP (TVL manager) | snapshot_interval | 4 hours | Frequency of TVL snapshots for all L2s |
| VIP (Lock Staking) | min_lock_period | 12 hours | Minimum lock period for any lock-staking position |
| VIP (Lock Staking) | max_lock_period | 6 days | Maximum lock period for all lock-staking positions (including esINIT positions) |
| VIP (Lock Staking) | max_delegation_slot | 50 | Maximum number of unique lock-staking positions per user |
| VIP (gauge vote) | cycle_start_time | Same as stage start time | Start time of the first gauge-vote cycle |
| VIP (gauge vote) | cycle_interval | 1 day | Length of a gauge-vote cycle |
| VIP (gauge vote) | voting_period | 23 hours | Duration of the voting window within a cycle |
| VIP (gauge vote) | max_lock_period_multiplier | 4 | Voting-power multiplier for the maximum lock duration |
| VIP (gauge vote) | min_lock_period_multiplier | 1 | Voting-power multiplier for the minimum lock duration |
| VIP (gauge vote) | pair_multipliers | 1 for all pairs | Voting-power multiplier applied to each enshrined liquidity pair |